<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>17648</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: Laser safety interlock is open
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Thermal</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The WLC (Write Laser Controller) has detected that the laser's 48V power supply
is missing.  This is likely due to an open safety interlock.  This error
condition will be automatically cleared when the interlock is closed.
</text></DescriptionText>
<DescriptionText><text>
This error code applies to Thermal Head firmware version 1.34 and above.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Ensure all safety interlocks are closed and retry operation.
</text></DescriptionText>
</OperatorAction>
<Cause>
A safety interlock is open.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:38 2008 PST
</Updated>
<Links>
</Links>
</Error>